Fiberglass Tank Installation
The CCG Molding Division manufactured these 9’ tall x 7′ tanks to store 15% sodium hypochlorite for use in the wastewater treatment process at the North Hudson Sewerage Authority in West New York, New Jersey. CCG’s in-house engineering group designed the tanks to solve a unique challenge: the tanks were located inside retaining walls where buoyant forces would try to lift the empty tanks off their anchor lugs. Our solution was a balsa-cored bottom on the tanks that securely resists any buoyant forces.